Obstetrics & Gynecology Email Alerts
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 2001;97:499-504
© 2001 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by OWEN, P.
Right arrow Articles by HOWIE, P. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by OWEN, P.
Right arrow Articles by HOWIE, P. W.

ORIGINAL RESEARCH

Interval Between Fetal Measurements in Predicting Growth Restriction

PHILIP OWEN, MD, MRCOG, SURINDRA MAHARAJ, MB, MRCOG, KHALID S. KHAN, MSc, MRCOG and P. W. HOWIE, MD, FRCOG

From the Department of Obstetrics, Glasgow Royal Maternity Hospital, Glasgow, Scotland; the Department of Obstetrics and Gynaecology, Birmingham Women’s Hospital, West Midlands, England; and the Department of Obstetrics and Gynaecology, Ninewells Hospital and Medical Scool, Dundee, Scotland.

Address reprint requests to: Philip Owen, MD, MRCOG, Department of Obstetrics Glasgow Royal Maternity Hospital Rottenrow Glasgow Scotland E-mail: philipowen1{at}hotmail.com

Objective: To determine the influence of the interval between fetal measurements on performance of fetal growth velocity for predicting infants with anthropometric features of fetal growth restriction (FGR).

Methods: Two hundred seventy-four low-risk women had serial fetal biometry at scheduled intervals. Growth velocity of the fetal abdominal area for each was calculated with 2-, 4-, and 6-week scan intervals in which the second measurement was the last scan before delivery. Fetal abdominal area velocity over a 4-week interval in the early third trimester also was included. Fetal growth restriction was defined as skinfold thickness under the tenth percentile, ponderal index under the 25th percentile, midarm circumference–to–occipitofrontal circumference ratio of under 21 standard deviation (SD). Test performance was expressed as likelihood ratios with 95% confidence intervals (CI).

Results: Fetal abdominal area velocity calculated over a 4-week interval predicted FGR with a likelihood ratio of 10.4 (95% CI 3.9, 26) for skinfold thickness; 9.5 (95% CI 4.6, 19) for ponderal index; and 4.7 (2.3, 8.4) for midarm circumference–to–occipitofrontal circumference ratio. Intermeasurement intervals of 6 weeks had a likelihood ratio of 8.5 (95% CI 4, 17) for skinfold thickness; 7.5 (95% CI 3.4, 16.1) for ponderal index; and 14 (6.7, 28) for midarm circumference–to–occipitofrontal circumference ratio. The likelihood ratios for the 2-week interval and the early third trimester 4-week interval were all less than 5.

Conclusion: Four- and 6-week measurement intervals were useful for predicting infants with FGR and were superior to a 2-week interval. Fetal growth velocity is influenced by proximity of the last fetal measurement to date of delivery, which adversely affects clinical use of growth velocity for predicting FGR.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American College of Obstetricians and Gynecologists.