Obstetrics & Gynecology Email Alerts
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 2000;96:634-635
© 2000 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davis, D. R.
Right arrow Articles by Hurd, W. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davis, D. R.
Right arrow Articles by Hurd, W. W.

INSTRUMENTS & METHODS

LAPAROSCOPIC SECONDARY PORTCONVERSION USING A REUSABLE BLUNT CONICAL TROCAR

Dan R. Davis, MD, Jeanne M. Schilder, MD and William W. Hurd, MD

From the Department of Obstetrics and Gynecology, Indiana University School of Medicine, Indianapolis, Indiana.

Address reprint requests to: William H. Hurd, MD Department of Obstetrics and Gynecology Indiana University School of Medicine 550 N. University Blvd., Room 2440 Indianapolis, IN 46202-5274 E-mail: whurd{at}iupui.edu

Background: During operative laparoscopy, large (10 mm or more) ancillary ports are often used for instrumentation and tissue removal. Although sharp pyramidal trocars can be used to place these ports, their use appears to increase the risk of vessel injury and herniation. We describe a simple and cost-effective technique for converting a 5-mm port to a 10- or 12-mm port using a blunt conical trocar.

Technique: When a larger port is required, a previously placed 5-mm port is removed, and the skin incision is lengthened. A reusable 10- or 12-mm blunt conical trocar with a threaded sleeve is placed through the incision. The fascial defect is located by probing and is dilated gently with the blunt tip. Once the tip is through the fascia, it is advanced through the peritoneal defect with a clockwise, twisting motion. Afterwards, the fascial defect is closed with a single, interrupted absorbable suture.

Experience: We have had no complications or difficulty when using this technique in 26 cases, either during or after surgery.

Conclusion: A reusable blunt conical trocar is a simple, safe, and cost-effective instrument for converting a 5-mm laparoscopic port into a 10- or 12-mm port.