Obstetrics & Gynecology Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 1999;94:48-51
© 1999 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by NEWMAN, R. B.
Right arrow Articles by SCARDO, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by NEWMAN, R. B.
Right arrow Articles by SCARDO, J.

ORIGINAL RESEARCH

Thoracic-Fluid Conductivity in Peripartum Women With Pulmonary Edema

ROGER B. NEWMAN, MD, HAROLD PIERRE, MD and JAMES SCARDO, MD

From theDivision of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Medical University of South Carolina, Charleston, South Carolina.

Address reprint requests to: Roger B. Newman, MD, Department of Obstetrics and Gynecology, Medical University of South Carolina, 171 Ashley Avenue, Charleston, SC 29425, E-mail: newmanr{at}musc.edu

Objective: To measure the level of thoracic-fluid conductivity associated with pulmonary edema in peripartum women by noninvasive thoracic electrical bioimpedance.

Methods: Between March 1994 and August 1996, 134 women were selected for thoracic electrical bioimpedance monitoring. Among them, 12 had pulmonary edema, 33 had severe preeclampsia, 17 had mild preeclampsia, and 72 were in uncomplicated early labor. Each subject’s highest thoracic-fluid conductivity measurement was related to her clinical presentation. The Kruskal-Wallis one-way analysis of variance was used to compare groups’ means. A receiver operating characteristic curve was used to identify thoracic-fluid conductivity values associated with pulmonary edema.

Results: Pulmonary edema was associated with severe preeclampsia in ten cases, urosepsis in one case, and postoperative volume overload in one case. Other than gestational age, there were no significant differences in maternal demographics between groups. Thoracic-fluid conductivity values in women with pulmonary edema (80.6 ± 18.3 kohm-1) were significantly higher than those in women with severe preeclampsia (62.8 ± 16.3 kohm-1), mild preeclampsia (53.3 ± 11.2 kohm-1), or early labor (41.3 ± 6.7 kohm-1). Thoracic-fluid conductivity of at least 65 kohm-1 best identified pulmonary edema (sensitivity 83.3%; specificity 86.9%; positive predictive value 38.5%; negative predictive value 98.1%).

Conclusion: Preeclampsia was associated with increased thoracic-fluid conductivity stratified between mild and severe disease. Thoracic-fluid conductivity of at least 65 kohm-1 was strongly associated with peripartum pulmonary edema. Women with values above 65 kohm-1 might be candidates for medical intervention even without overt clinical symptoms.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American College of Obstetricians and Gynecologists.