Obstetrics & Gynecology Email Alerts
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 1999;93:189-192
© 1999 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by KIRK, J. S.
Right arrow Articles by WEINHOUSE, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by KIRK, J. S.
Right arrow Articles by WEINHOUSE, E.

ORIGINAL RESEARCH

Fetal Cardiac Asymmetry: A Marker for Congenital Heart Disease

JANET S. KIRK, MD, CHRISTINE H. COMSTOCK, MD, WESLEY LEE, MD, RAMADA S. SMITH, MD, THOMAS W. RIGGS, MD and ELLIOTT WEINHOUSE, MD

From the Division of Fetal Imaging, Department of Obstetrics and Gynecology, and Division of Pediatric Cardiology, Department of Pediatrics, William Beaumont Hospital, Royal Oak, Michigan.

Address reprint requests to: Janet S. Kirk, MD Department of Fetal Imaging Department of Obstetrics and Gynecology William Beaumont Hospital 3601 West Thirteen Mile Road Royal Oak, MI 48073

Objective: To determine the sensitivity of prenatally detected fetal cardiac asymmetry as a sonographic marker for congenital heart disease.

Methods: The normal ratios of pulmonary artery to aorta diameters and of right ventricle to left ventricle diameters were derived from normal fetuses scanned at 17 weeks or more in a 65-month period. Cross-sectional diameters of cardiac ventricles and great arteries were measured at the level of the valves at the time of the scan. Fetuses with confirmed cardiac anomalies detected prenatally during the study were examined to identify how many had cardiac asymmetry, determined by abnormal ratios.

Results: Linear regression analysis of the group of 881 normal fetuses showed the normal pulmonary artery to aorta diameter ratio remained constant throughout pregnancy and the normal right ventricle to left ventricle ratio increased slightly with progressing gestational age. The 90% confidence intervals were 0.79, 1.24 for the right ventricle to left ventricle ratio and 0.84, 1.41 for the pulmonary artery to aorta ratio. Of the 73 fetuses with abnormal hearts, 66% had either ventricular or great artery asymmetry (at least one of the two ratios was abnormal). However, if no asymmetry was present, the cardiac defect was more likely to be a minor one.

Conclusion: Cardiac asymmetry was present in two-thirds of fetuses with cardiac anomalies diagnosed prenatally. If cardiac asymmetry is found, a more thorough examination of the fetal heart is indicated.




This article has been cited by other articles:


Home page
J Ultrasound MedHome page
P. Jeanty, R. Chaoui, I. Tihonenko, and F. Grochal
A Review of Findings in Fetal Cardiac Section Drawings: Part 1: The 4-Chamber View
J. Ultrasound Med., November 1, 2007; 26(11): 1601 - 1610.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
J. M. Smrcek, C. Berg, A. Geipel, R. Fimmers, K. Diedrich, and U. Gembruch
Early Fetal Echocardiography: Heart Biometry and Visualization of Cardiac Structures Between 10 and 15 Weeks' Gestation
J. Ultrasound Med., February 1, 2006; 25(2): 173 - 182.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American College of Obstetricians and Gynecologists.