Obstetrics & Gynecology Email Alerts
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 1996;87:969-974
© 1996 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Guzman, E.
Right arrow Articles by Hanley, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Guzman, E.
Right arrow Articles by Hanley, M

Articles

The efficacy of individual computer heart rate indices in detecting acidemia at birth in growth-restricted fetuses

ER Guzman, AM Vintzileos, M Martins, C Benito, C Houlihan, and M Hanley

OBJECTIVE: To determine the efficacy of individual fetal heart rate (FHR) indices, as determined by computer analysis of the FHR tracing, in detecting fetal acidemia at birth in growth-restricted fetuses. METHODS: The study population consisted of 38 growth-restricted fetuses at 26-37 weeks' gestation from pregnancies with abnormal uterine and/or umbilical artery Doppler velocimetry. The 1-hour FHR tracing was analyzed by computer within 4 hours of cesarean birth before the onset of labor. Umbilical artery cord blood was collected at birth, and pH was determined within 5 minutes of collection. RESULTS: On linear regression, the duration of episodes of low variation in minutes (r = -0.77, r2 = 0.59) and short-term (r = 0.72, r2 = 0.52) and long-term (r = 0.69, r2 = 0.47) variation in milliseconds were significantly related to umbilical artery pH at birth, and more so than the number of accelerations of ten (r = 0.57, r2 = 0.32) and 15 (r = 0.38, r2 = 0.14) beats per minute. There were significant differences in computer measurements of FHR accelerations and variation between the umbilical artery pH categories of acidemia (pH less than 7.20), preacidemia (7.20-7.25), and nonacidemia (greater than 7.25). Stepwise regression revealed that episodes of low variation best described the model for predicting umbilical artery pH at birth (P < .001), with no improvement provided by the addition of other computer-analyzed FHR characteristics. CONCLUSION: In this population of growth-restricted fetuses delivered by elective cesarean, the computer indices of duration of episodes of low variation and short-term and long-term variation were significantly associated with umbilical artery pH and predicted umbilical artery acidemia at birth.


This article has been cited by other articles:


Home page
Obstet GynecolHome page
S. K. Agrawal, F. Doucette, R. Gratton, B. Richardson, and R. Gagnon
Intrapartum Computerized Fetal Heart Rate Parameters and Metabolic Acidosis at Birth
Obstet. Gynecol., October 1, 2003; 102(4): 731 - 738.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS