Obstetrics & Gynecology Email Alerts
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 1978;52:673-677
© 1978 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by SHER, G.
Right arrow Articles by KRAYBILL, E. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by SHER, G.
Right arrow Articles by KRAYBILL, E. N.

Assessing Fetal Lung Maturation by the Foam Stability Index Test

GEOFFREY SHER, MD, BERNARD E. STATLAND, MD, PhD, DENNIS E. FREER, MS and ERNEST N. KRAYBILL, MD

From the Departments of Obstetrics and Gynecology, Pathology, Medicine, Biochemistry, and Pediatrics at the University of North Carolina Medical School and the Department of Hospital Laboratories at North Carolina Memorial Hospital, Chapel Hill, North Carolina

Abstract

An assay has been developed and evaluated that quantifies the surface tension lowering ability of amniotic fluid surfactant. The formation of stable foam following vigorous shaking of amniotic fluid was evaluated by the addition of various amounts of dipalmitoyl lecithin in a solution of ethanol and saline and by fine adjustments of the ethanol volume fraction in the final assay mixture. The foam stability index (FSI) for a particular sample of amniotic fluid was defined as the highest ethanol volume fraction that would permit the formation of stable foam after vigorously shaking a mixture of ethanol and amniotic fluid. The assay is referred to as the FSI test. We report the FSI values in amniotic fluid specimens from 59 patients obtained within 72 hours of delivery. The L/S ratio was measured in SO of the same 59 specimens. We observed 6 cases of neonatal hyaline membrane disease (HMD) and 2 cases of transient tachypnea of the newborn (TTNB) in this study. No cases of HMD or TTNB occurred with FSI values of greater than 0.47, while 2 cases of HMD were recorded in association with L/S ratios of 2.5 and 2.8, respectively. The potential clinical value of the FSI test is discussed.