Obstetrics & Gynecology Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 2005;106:913-918
© 2005 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mollberg, M.
Right arrow Articles by Ladfors, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mollberg, M.
Right arrow Articles by Ladfors, L.

ORIGINAL RESEARCH

Risk Factors for Obstetric Brachial Plexus Palsy Among Neonates Delivered by Vacuum Extraction

Margareta Mollberg, RNM1, Henrik Hagberg, MD, PhD1, Börje Bager, MD2, Håkan Lilja, MD, PhD1 and Lars Ladfors, MD, PhD1

From the 1Perinatal Center, Department of Obstetrics and Gynecology, Institute for the Health of Women and Children, Sahlgrenska University Hospital, Göteborg, Sweden; and 2Child Habilitation, Central Hospital, Skövde, Sweden.

OBJECTIVE: The risk of obstetric brachial plexus palsy (OBPP) is increased in infants delivered instrumentally. The aim of this study was to identify risk factors for OBPP and to evaluate the association between possible risk factors linked to the duration of the vacuum extraction procedure and the subsequent risk.

METHODS: A population-based retrospective design was adopted. Using a national registry of operative vaginal deliveries linked to the Medical Birth Registry in Sweden, we evaluated by univariate and multiple logistic regression analyses the risk factors for OBPP in 13,716 women delivered by vacuum extraction. The variables assessed in the multiple logistic regression analysis were shoulder dystocia, fetal birth weight of 3,999 g or greater, fundal pressure, number of tractions, vacuum application time, parity, vacuum silicone cup, epidural anesthesia, and fetal head at the level of the ischial spines at vacuum application time.

RESULTS: Obstetric brachial plexus palsy was recorded in 153 (1.1%) infants. The following variables increased significantly the risk of OBPP in the newborn: shoulder dystocia (odds ratio 16.0; 95% confidence interval 8.9–28.7), fetal birth weight of 3,999 g or greater (7.1; 4.8–10.5), and administration of fundal pressure (1.6; 1.1–2.3). The probability of the risk of OBPP in vacuum-assisted deliveries increased in relation to vacuum extraction time (minutes).

CONCLUSION: Shoulder dystocia in the setting of vacuum extraction is a prominent risk factor for OBPP in the newborn. The risk of OBPP increases with the time required for vacuum extraction.

LEVEL OF EVIDENCE: II-3