Obstetrics & Gynecology Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 2005;105:458-465
© 2005 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Althaus, J. E.
Right arrow Articles by Graham, E. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Althaus, J. E.
Right arrow Articles by Graham, E. M.
Related Collections
Right arrow General obstetrics
Right arrow Maternal/fetal physiology
Right arrow Obstetric complications of pregnancy

ORIGINAL RESEARCH

Can Electronic Fetal Monitoring Identify Preterm Neonates With Cerebral White Matter Injury?

Janyne E. Althaus, MD, Scott M. Petersen, MD, Harold E. Fox, MD, MSc, Cynthia J. Holcroft, MD and Ernest M. Graham, MD

From the Department of Gynecology and Obstetrics, Division of Maternal–Fetal Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland.

OBJECTIVE: Although preterm delivery occurs in only 10% of all births, these infants are at high risk for cerebral white matter injury and constitute a third of all cerebral palsy cases. Our objective was to estimate if electronic monitoring can identify preterm fetuses diagnosed with brain injury during the neonatal period.

METHODS: In this case-control study, 150 consecutive neonates with ultrasonography-diagnosed cerebral white matter injury were matched by gestational age within 7 days to 150 controls with normal head ultrasonograms. Tracings were retrieved for 125 cases (83%) and 121 controls (81%) and reviewed by 3 perinatologists blinded to outcome. Vaginal (64 cases, 72 controls) and cesarean deliveries (61 cases, 49 controls) were analyzed separately.

RESULTS: There was no difference in baseline heart rate, tachycardia, bradycardia, short-term variability, accelerations, reactivity, number or types of decelerations, or bradycardic episodes between cases and controls in either the vaginal or cesarean delivery groups. For the 6 neonates with metabolic acidosis severe enough to increase the risk for long-term neurologic morbidity, there was a significant increase in baseline amplitude range less than 5 beats per minute; however, its positive predictive value in predicting severe metabolic acidosis was only 7.7%. Increasing late decelerations were associated with decreasing umbilical arterial pH and base excess, but were not significantly different in the acidosis and control groups (1.0 ± 1.8, 0.55 ± 1.23 late decelerations per hour, P = .39).

CONCLUSION: Although decreased short-term variability and increased late decelerations are associated with decreasing umbilical arterial pH and base excess, electronic fetal monitoring is unable to identify preterm neonates with cerebral white matter injury.

LEVEL OF EVIDENCE: II-2




This article has been cited by other articles:


Home page
Reproductive SciencesHome page
S. Blad, A.-K. Welin, I. Kjellmer, K.G. Rosen, and C. Mallard
ECG and Heart Rate Variability Changes in Preterm and Near-Term Fetal Lamb Following LPS Exposure
Reproductive Sciences, July 1, 2008; 15(6): 572 - 583.
[Abstract] [PDF]


Home page
Obstet GynecolHome page
E. M. Graham, S. M. Petersen, D. K. Christo, and H. E. Fox
Intrapartum Electronic Fetal Heart Rate Monitoring and the Prevention of Perinatal Brain Injury.
Obstet. Gynecol., September 1, 2006; 108(3): 656 - 666.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS