Obstetrics & Gynecology Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 2004;104:952-956
© 2004 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Albright, T. S.
Right arrow Articles by Samuels, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Albright, T. S.
Right arrow Articles by Samuels, P.
Related Collections
Right arrow Basic Science
Right arrow Maternal/fetal physiology
Right arrow Obstetric complications of pregnancy
Right arrow Pathology

ORIGINAL RESEARCH

Evaluation of the Effect of Meconium on Assessment of Fetal Lung Maturity Status by TDxFLM II Testing

Todd S. Albright, DO*, David F. Colombo, MD*, Elizabeth Euscher, MD{dagger} and Philip Samuels, MD*

From the Departments of *Obstetrics and Gynecology and {dagger}Pathology, The Ohio State University College of Medicine and Public Health, Columbus, Ohio.

Address reprint requests to: Todd S. Albright, DO, 10193 Cape Ann Drive, Columbia, MD 21046; e-mail: live2bike{at}comcast.net.

OBJECTIVE: To evaluate the effect of meconium contamination on the TDxFLM II assay.

METHODS: Amniotic fluid was collected from patients undergoing amniocentesis for obstetric indications between 31 and 40 weeks of gestation. A baseline TDxFLM II value was obtained and compared with amniotic fluid contaminated with 1%, 5%, and 10% meconium by weight.

RESULTS: Twenty-one samples were studied, and in every case the TDxFLM II value decreased once the meconium was added. There was no consistent rate of decrease that correlated with the percentage of meconium added.

CONCLUSION: Meconium contamination decreases the TDxFLM II value. A clinician who performs this test in the presence of meconium can be reassured that the contamination will not give an artificially elevated result. If the result is in the mature range, one can be confident that the result would only be higher if meconium were not present.