Obstetrics & Gynecology Email Alerts
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 2004;103:681-685
© 2004 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Munro, M. G.
Right arrow Articles by Tarnay, C. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Munro, M. G.
Right arrow Articles by Tarnay, C. M.
Related Collections
Right arrow Endoscopic surgery
Right arrow Gynecologic surgery

ORIGINAL RESEARCH

The Impact of Trocar-Cannula Design and Simulated Operative Manipulation on Incisional Characteristics: A Randomized Trial

Malcolm G. Munro, MD and Christopher M. Tarnay, MD

From the Department of Obstetrics and Gynecology, David Geffen School of Medicine at UCLA, University of California, Los Angeles, California..

OBJECTIVE: To evaluate the hypothesis that abdominal muscular and fascial defects associated with 12-mm blunt conical trocar-cannula system will be similar to those associated with 8-mm pyramidal trocar-cannula system, both with and without simulated operative movements.

METHODS: A randomized trial was performed in an animal (white swine) model. Four trocar-cannula system groups were evaluated: group A, 12-mm blunt conical system, no operative manipulations; group B, 12-mm blunt conical system, standardized operative manipulation; group C, 8-mm pyramidal system, no operative manipulations; group D, 8-mm pyramidal system with standardized operative manipulation. These 4 groups were randomly assigned across 8 animals and 6 locations for a total of 48 insertions. After the cannulas were removed, the skin and subcutaneous tissues were dissected to expose the fascial wounds. Maximal incisional length, wound area, and muscle damage score were determined for each defect.

RESULTS: Mean wound area was 8.58 mm2 in group A, 9.71 mm2 in group B, 9.83 mm2 in group C, and 9.63 mm2 in group D. Incisional length was 9.16 mm in group A, 9.61 mm in group B, 9.14 mm in group C, and 8.52 mm in group D. There were no statistically significant differences between any 2 groups. Mean muscle injury scores were also similar for all groups.

CONCLUSIONS: Twelve-millimeter conical trocar-cannula systems create fascial defects similar to those of 8-mm pyramidal systems, both immediately after insertion and after simulated operative manipulations. Given the historical low risk of wound dehiscence and hernia associated with pyramidal devices less than 10-mm in outside diameter, fascial closure of wounds created by conical systems may be unnecessary.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American College of Obstetricians and Gynecologists.