Obstetrics & Gynecology Email Alerts
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Obstetrics & Gynecology 2002;100:1190-1195
© 2002 by The American College of Obstetricians and Gynecologists
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hayman, R.
Right arrow Articles by Arulkumaran, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hayman, R.
Right arrow Articles by Arulkumaran, S.

ORIGINAL RESEARCH

Clinical Evaluation of a "Hand Pump" Vacuum Delivery Device

Richard Hayman, MRCOG, DM, Jeanette Gilby, RM, MA and Sabaratnam Arulkumaran, FRCOG, PhD

From the Department of Obstetrics and Gynecology, Derby City General Hospital, Derby, United Kingdom.

Address reprint requests to: Richard Hayman, MRCOG, DM, City Hospital, Department of Obstetrics and Gynecology, Nottingham, NG5 1PB, United Kingdom; E-mail: richard.hayman{at}nottingham.ac.uk.

OBJECTIVE: To evaluate the clinical performance of a hand-held vacuum delivery system.

METHODS: Between December 1999 and September 2000, a prospective audit was undertaken of all vacuum deliveries performed at Derby City General Hospital.

RESULTS: In this period, 3296 deliveries occurred, of which 317 (9.6%) were by vacuum. Of these, data were collected on 300 (94.6%), 78 deliveries with the hand-held vacuum and 222 with standard vacuum. There were no differences in the demographic profiles, indication, gestational age at delivery, or birth weights between the two groups (P > .05 in all instances). In all types of delivery, nonrotational and rotational, the hand-held vacuum performed comparably to its contemporaries with no increase in delivery "failures" being noted. There were no differences in the extent or frequency of maternal injuries between the instruments, and other than transient scalp abrasions, there were no significant fetal injuries.

CONCLUSION: The hand-held vacuum delivery system is a functionally effective addition to the practitioners’ "armory," providing an alternative to the standard metal and silastic cups.




This article has been cited by other articles:


Home page
Obstet GynecolHome page
M. L. Schwartz
Clinical Evaluation of a "Hand Pump" Vacuum Delivery Device
Obstet. Gynecol., June 1, 2003; 101(6): 1353 - 1353.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS